Cornwall Austin Seven Club
creating interest in Austin Sevens (1922 - 1939)   

 

Celebrating
the 90th Anniversary
of the Austin Seven
and the 75th Anniversary
of the Austin Big Seven

 

 

Home Page
welcome to our website

About Us
information about our Club

Contacts
our Officers and Committee

Events Diary
our events for the
months ahead

Event Reports
from the last four months

The Kernow Rumble
our 10th Anniversary Rally
July 2010

Member's Cars
a selection of
our active 'Sevens'

Joys of being a 7'er
and a few stories

Do you fancy an
Austin Seven?

advice on buying a 'Seven'

Photo Gallery
of our past activities and 'Sevens' in close up

From the Past
items from 1920/30s magazines

Registration Marks
in the UK from 1903

Help at the roadside
fuel and electrical problems

Austin Seven Journal
advice for Austin Agents
& Service Depots

Technical Articles
our members help you with various tasks.

Technical Advice
from old magazines

Data Pages
info on 'Sevens'

Guide to Parts
and Services

sources of spares etc

Quick Tips
a few handy ideas

Other Articles
of interest, not technical

Austin Seven Books
some of the books available

Visiting Cornwall
if you come our way

A7CA and FBHVC
CA7C is an active supporter

  Links to other
Austin Seven Sites

Website Policy
on advertisements & links

     

 

 

Last updated:
04 February 2012

 

 

 

012345678901234567

 

How it Works - the Cut-out 

The charging system of the Austin Seven primarily consists of a dynamo to produce an electric current and a battery in which to store the charge. In between these two is an automatic switch, known as a Cut-out. Without the cut-out, the battery would be charged whenever the dynamo is rotated sufficiently fast by the engine, but would be rapidly discharged by trying to operate the dynamo as a motor when the engine revs are not high enough – particularly when the engine is stationary. Note that the ignition switch does NOT disconnect the dynamo from the battery; it only disconnects the ignition circuit itself, (plus a few auxiliary devices such as stop lights). The ignition switch is therefore not relevant to the cut out operation or charging circuit. 

There have been a number of variants during the period over which the cars were manufactured. However, they all have the same function and all have very similar operation. Each Cut-out has a set of spring loaded contacts mounted on a mechanical rocker, known as an armature, plus two electromagnets which are arranged so as to pull and push on this armature. One electromagnet is connected between the dynamo output terminal “D” and earth, (the “shunt” winding”), and the other, (the “series” winding) is connected in series with the battery usually marked “A” and the cut-out contacts. Note that, depending on cut-out type, these windings may be on separate bobbins or combined on one bobbin. Irrespective of type, the shunt winding is composed of many turns of thin wire, whilst the series winding is very few turns of substantially thicker wire.

 

 

 

 

 

 

 

 


 


Example Cut-out Circuit


 

 

 

With the engine stationary, it is necessary for the battery to be disconnected from the dynamo, to prevent the “motor” action described above. Hence, the contacts must be open. This is the resting state of the cut-out.  

As the engine is started and the revs increased, the dynamo output voltage will rise. This output voltage appears across the shunt winding, making it act as an electromagnet. As the series winding has one end connected to an open contact, it plays no part at this stage. Eventually, (at fast tickover), the dynamo voltage will reach a value that would be high enough to prevent current flowing from the battery to the dynamo, but would allow current to flow from the dynamo to the battery – the normal charging method. The shunt winding is arranged so that when the dynamo output voltage reaches this value, it produces a sufficiently strong magnetic field to pull on the armature overcoming the spring force and close the contacts. The battery is now being charged. For 6V systems, this should occur at approximately 6.5V; for 12V, this occurs at 13.5V.  As soon as the contacts are closed, the shunt winding is now also connected across the battery. This gives a latching action as the battery now also supplies current for the shunt winding. In this state, the contacts would still be pulled shut until the battery voltage dropped to a low level irrespective of the dynamo output, as the electromagnet is now being operated by the battery.

Consequently, it is necessary to counteract this force so that the spring can pull the contacts apart to disconnect the battery. This is the function of the second or “series” winding. 

The Series winding produces a force on the armature which is proportional to the current flowing either to or from the battery, and which changes direction with the direction of current flow. When the battery is being charged, the force acts to add to the pulling force from the shunt winding, causing the contacts to be held firmly shut. However, when the dynamo output falls so that there is a current from the battery to the dynamo, the force is now in the opposite direction and opposes that of the shunt winding. When the force from the series winding equals that of the shunt, then the armature is released for the spring to open the contacts. 

If the engine is stopped at this point, the battery is safely disconnected from the dynamo. If the revs rise, the force from the shunt winding will close the contacts again.

This can be seen in operation from the behaviour of the ammeter. With all other electrical loads off, (note that the ammeter measures all current flow from the battery, not just that to the dynamo), and the engine running at a fast tickover, the ammeter will settle in the charging side of the scale. When the revs are allowed to drop, the ammeter will move to the discharge side and then suddenly fall back nearer to zero. This sudden fall back occurs when the series winding has sufficient current flowing in the discharge direction to counteract the closing force from the shunt winding and the contacts are opened. The charging warning light will operate at the same time.  No current flows to the dynamo; the remaining discharge shown is actually the current required by the ignition circuit.

 


Type E 1922-1923

 

Type CF1 1924-1931

 

 

 

 

Type CF3 1931-1933

 

Type GFR or GFR2 1934-1937

 

 

 

This article, written by Geoff Hardman, originally appeared in CA7C Seven Focus in Nov 2006 pp6-8.

 

Copyright © 2009 Cornwall Austin Seven Club, M J Watts & D A Castle to whom any questions or comments about this website should be addressed.